Research prototype, not for clinical diagnosis.
LOWER EXTREMITY — NOMINAL

NEUROSCAN/4█

Multi-modal MRI brain tumour segmentation. Four-channel MRI ingestion (T1, T1ce, T2, FLAIR) with 31.5M-parameter Attention U-Net delineation of peritumoral edema, enhancing core, and necrotic tissue.

CRANIAL LOCK // R-PARIETAL LOBE
Edema Halo (L2)
WT 90.80% F1
Enhancing Rim (L3)
ET 82.76% F1
Necrotic Core (L1)
TC 85.23% F1
SKULL TRANSPARENCY: 84% · LEFT-CLICK & DRAG TO ROTATE BRAIN
G-01GANTRY TRAVEL
000%0 / 1840 mm
G-023D SPIN TRACKPAD (LEFT-CLICK DRAG)
✥ HOLD LMB & DRAG TO SPIN0° / 0°
G-03TARGET LOCK
SCANNING AXIAL STATIONS...

SCROLL TO ADVANCE GANTRY TO BRAIN ↓

G-04MANUAL OVERRIDE
STATION 02 // DIAGNOSTIC WORKSTATION

MULTI-MODAL SLICE CONSOLE

PATIENT TAG
BRATS20_TRAINING_369 · GLIOBLASTOMA
ET RIM PRESENT
P-01ORIENTATION PLANE
ACTIVE STATIONSLICE 095/155
P-02GANTRY SLICE SCRUBBER
M-01AXIAL CRT MONITOR // FLAIR WEIGHTED
VOX (105,89,95)NECROTIC CORE [NCR · L1]
EDEMA ENHANCING NECROTIC
C-01MRI SEQUENCE
MODALITY DIAL
C-02SUB-REGION LAYERS
C-03LIVE TELEMETRY READOUTS (7-SEG)
DICE / F1%
JACCARD / J1%
HAUSDORFF 95mm
TUMOR VOLcm³
EDEMA (ED)
67.9 cm³
ENHANCING (ET)
12.8 cm³
NECROTIC (NCR)
2.4 cm³
STATION 03 // VOLUMETRIC TOMOGRAPHY

3D CONTOUR STACK RECONSTRUCTION

Drag inside the CRT viewport to orbit the reconstructed brain mesh. Scrub STACK to watch 2D axial contours assemble into the 3D lesion.

V-01ISOMETRIC WIREFRAME HOLOGRAM // DRAG TO ROTATE
R-PARIETAL GLIOMA· 38/38 SLICES
● CORTICAL MESH● WHOLE TUMOR (WT)● ENHANCING RIM (ET)
ORBIT: LMB DRAG · ZOOM: WHEEL
V-02CONTOUR STACK FADERS
V-03MESH & TURNTABLE SWITCHES
V-043D VOLUMETRIC INTEGRATOR
3D DICE%
TUMOR COREcm³
DOCUMENT DWG-89-402 // TECHNICAL SYSTEM SCHEMATIC

SIGNAL PROCESSING & NEURAL ARCHITECTURE

REV: 3.1 (ATTN-UNET-F64)
PARAMS: 31,564,016 · AMP FP16
STAGE A4-CHANNEL NIfTI INGESTFLAIR · T1 · T1ce · T2(4, 240, 240, 155) float32[CLICK TO INSPECT]STAGE BZ-SCORE & 192² CROPPARENCHYMA NORMALIZATION(4, 155, 192, 192) float16[CLICK TO INSPECT]STAGE C31.5M ATTENTION U-NET64 → 128 → 256 → 512 → 1024Logits (B, 4, 192, 192)[CLICK TO INSPECT]STAGE DTTA ×3 & CALIBRATIONSUB-COMPARTMENT THRESHOLDSProbs (4, 192, 192) → uint8[CLICK TO INSPECT]STAGE E3D VOLUMETRIC MASKWT · TC · ET DELINEATION(240, 240, 155) uint8 NIfTI[CLICK TO INSPECT]
STAGE C // SPECIFICATION

31.5M ATTENTION U-NET

TENSOR: Logits (B, 4, 192, 192)
EQ: α = σ( ψ( ReLU(W_g g + W_x x) ) )
ENGINEERING NOTES
  • [1]4 encoder-decoder levels with DoubleConv (Conv3×3 + BatchNorm + ReLU).
  • [2]Additive Attention Gates filter skip connections to suppress healthy tissue noise.
  • [3]Trained with Weighted Dice (1.2) + Focal Loss (1.5, γ=2.0) under FP16 AMP.
STATION 05 // TELEMETRY & ABLATION LOGS

OSCILLOSCOPE CONVERGENCE TRACES

OSC-1TEK-CRT DUAL-BEAM OSCILLOSCOPE // MEAN DICE (EPOCHS 01–25)
91.0%89.2%87.4%85.6%83.8%82.0%EP 01EP 05EP 10EP 15EP 20EP 25
CURSOR: EPOCH 25 · LOSS 0.1803
OSC-2STAGE 3 HEAVY (31.5M) VALIDATION LOCK
BALANCED ACC%
VOXEL ACC%
WHOLE TUMORF1 %
TUMOR COREF1 %
ENHANCING ETF1 %
JOINT F1%
CHECKPOINT: best_attention_heavy.pt

Trained 25 epochs on NVIDIA RTX Pro 6000 (55-case held-out validation split, TTA ×3 + calibrated sub-region thresholds).

TTY-01TELETYPE BENCHMARK READOUT // INTERNAL VAL SPLIT VS PUBLISHED BRATS 2020 REFS
STAGE / REFARCHITECTURE & CONFIGURATIONWT F1TC F1ET F1MEAN F1BAL. ACCVOX. ACC
FORM MED-AI-09 // REGULATORY & SAFETY DISCLOSURE

ETHICS, INTER-RATER LIMITS & CLINICAL SCOPE

RESEARCH PROTOTYPE
NOT FOR CLINICAL DIAGNOSIS
01 // NON-DIAGNOSTIC STATUS

Research prototype, not for clinical diagnosis. NEUROSCAN/4 is an academic and engineering demonstration trained on retrospective research scans (MICCAI BraTS 2020). It has not been cleared by the FDA, CE, or CDSCO and must never be used to guide patient care, biopsy targeting, or neurosurgical resection margins.

02 // RADIOLOGIST INTER-RATER CEILING

On glioblastoma MRI, board-certified neuroradiologists exhibit an inter-observer Dice agreement of ~82%–85% on the microscopic enhancing rim (ET). Evaluation numbers reported here reflect a 55-patient held-out split from the BraTS 2020 training archive.

03 // KNOWN ARCHITECTURAL LIMITS

While 2D axial slices with Test-Time Augmentation and 3D connected-component filtering achieve fast inference and high overlap, out-of-plane anisotropic spacing and scanner-specific coil artifacts require site-specific domain calibration before clinical translation.

CHECKPOINT VERIFIED: checkpoints/best_attention_heavy.pt (31.5M PARAMS)DATASET: RSNA-ASNR-MICCAI BRATS 2020 · CC-BY-NC